Membrane Adsorption Procedure in Flow-Through Mode

Overview

A Membrane Adsorption in Flow-Through Mode Procedure can be created by selecting the following menu option:
Unit Procedures } Chromatography/Adsorption } Membrane Adsorption in Flow-Through Mode

MA_FwTh.bmp

 

Operating Mode

Batch/Semi-Continuous

Host Equipment

Membrane Adsorber (MA)

Emissions Port (Vent)

No

Special Input/Output Ports

Yes

 

 

This unit procedure simulates membrane adsorption in flow-through mode. The procedure can be executed in a batch/semi continuous mode only.

Special Inputs / Outputs

●      Feed: the designated input port for the feed stream.

●      Product: the designated output port for the flow-through stream.

Operations

The following operation types are currently supported in the context of this unit procedure:

●      Equilibrate, see Membrane Adsorber (MA) Equilibration

●      Flow Through, see Membrane Adsorber (MA) Flow-Through

●      Flush, see Membrane Adsorber (MA) Flush

●      Hold, see Holding

●      Regenerate, see Membrane Adsorber (MA) Regeneration

●      Sanitize, see Membrane Adsorber (MA) Sanitization

●      Strip, see Membrane Adsorber (MA) Strip

SEe Also

The following procedures offer a similar functionality:

●      Gel Filtration Procedure

●      Packed Bed Adsorption (PBA) Chromatography Procedure (Simplified)

●      Packed Bed Adsorption (PBA) Chromatography Procedure (Detailed) in Bind-and-Elute Mode

●      Packed Bed Adsorption (PBA) Chromatography Procedure (Detailed) in Flow-Through Mode

●      Expanded Bed Adsorption (EBA) Chromatography Procedure

●      Membrane Adsorption Procedure in Bind-and-Elute Mode