Membrane Adsorption Procedure in Bind-and-Elute Mode

Overview

A Membrane Adsorption in Bind-and-Elute Mode Procedure can be created by selecting the following menu option:
Unit Procedures } Chromatography/Adsorption } Membrane Adsorption in Bind-and-Elute Mode

MA_BdEl.bmp

 

Operating Mode

Batch/Semi-Continuous

Host Equipment

Membrane Adsorber (MA)

Emissions Port (Vent)

No

Special Input/Output Ports

Yes

 

 

This unit procedure simulates membrane adsorption in bind-and-elute mode. The procedure can be executed in a batch/semi continuous mode only.

Special Inputs / Outputs

●      Feed: the designated input port for the feed stream.

Operations

The following operation types are currently supported in the context of this unit procedure:

●      Elute, see Membrane Adsorber (MA) Elution

●      Equilibrate, see Membrane Adsorber (MA) Equilibration

●      Flush, see Membrane Adsorber (MA) Flush

●      Hold, see Holding

●      Load, see Membrane Adsorber (MA) Loading

●      Regenerate, see Membrane Adsorber (MA) Regeneration

●      Sanitize, see Membrane Adsorber (MA) Sanitization

●      Wash, see Membrane Adsorber (MA) Wash

SEe Also

The following procedures offer a similar functionality:

●      Gel Filtration Procedure

●      Packed Bed Adsorption (PBA) Chromatography Procedure (Simplified)

●      Packed Bed Adsorption (PBA) Chromatography Procedure (Detailed) in Bind-and-Elute Mode

●      Packed Bed Adsorption (PBA) Chromatography Procedure (Detailed) in Flow-Through Mode

●      Expanded Bed Adsorption (EBA) Chromatography Procedure