A Membrane Adsorption in Bind-and-Elute Mode Procedure can be created by selecting the following menu option:
Unit Procedures } Chromatography/Adsorption } Membrane Adsorption in Bind-and-Elute Mode
|
Operating Mode |
Batch/Semi-Continuous |
Host Equipment |
||
Emissions Port (Vent) |
No |
|
Special Input/Output Ports |
Yes |
|
|
|
This unit procedure simulates membrane adsorption in bind-and-elute mode. The procedure can be executed in a batch/semi continuous mode only.
● Feed: the designated input port for the feed stream.
The following operation types are currently supported in the context of this unit procedure:
● Elute, see Membrane Adsorber (MA) Elution
● Equilibrate, see Membrane Adsorber (MA) Equilibration
● Flush, see Membrane Adsorber (MA) Flush
● Hold, see Holding
● Load, see Membrane Adsorber (MA) Loading
● Regenerate, see Membrane Adsorber (MA) Regeneration
● Sanitize, see Membrane Adsorber (MA) Sanitization
● Wash, see Membrane Adsorber (MA) Wash
The following procedures offer a similar functionality:
● Packed Bed Adsorption (PBA) Chromatography Procedure (Simplified)
● Packed Bed Adsorption (PBA) Chromatography Procedure (Detailed) in Bind-and-Elute Mode
● Packed Bed Adsorption (PBA) Chromatography Procedure (Detailed) in Flow-Through Mode
● Expanded Bed Adsorption (EBA) Chromatography Procedure
● Membrane Adsorption Procedure in Bind-and-Elute ModeMembrane Adsorption Procedure in Bind-and-Elute Mode