Reverse Osmosis (Feed and Bleed) Procedure

Overview

A Reverse Osmosis (Feed and Bleed) Procedure can be created by selecting the following menu option:
Unit Procedures } Filtration } Reverse Osmosis (Feed and Bleed)

ReverseOsmosisFilter.bmp

 

Operating Mode

Batch/Semi-Continuous

Host Equipment

Reverse Osmosis Filter

Emissions Port (Vent)

No

Special Input/Output Ports

Yes

 

 

Feed and bleed (continuous) reverse osmosis (RO) is mainly used for removing ionic species and medium MW solutes from water solutions in plants that require large throughputs. Typical applications include water desalination and ultrapure water production. In the biotech field, RO filters have been used to concentrate and purify antibiotics.

Special Inputs / Outputs

      Filtrate: the designated output port for the filtrate.

      Concentrate: the designated output port for the concentrate.

Operations

The following operation types are currently supported in the context of this unit procedure:

      Concentrate (Feed & Bleed), see Feed & Bleed Concentration (Continuous Membrane Filtration)

      CIP, see Clean-In-Place (CIP)

      Hold, see Holding

      SIP, see Steam-In-Place (SIP)

SEe Also

The following procedures offer a similar functionality:

      Reverse Osmosis (Batch) Procedure

      Microfiltration (Feed and Bleed) Procedure

      Ultrafiltration (Feed and Bleed) Procedure