Reverse Osmosis Filter

Overview

AppendixB00038.jpg

 

Size / Design Variable

Filter Area

Costing Variable
(Built-in Model)

Filter Area

Costing Variable
(User-Defined Model)

Filter Area in m2 

Emissions Port

No

Hosts

Reverse Osmosis (Batch) Procedure

 

Reverse Osmosis (Feed and Bleed) Procedure

 

A Reverse Osmosis Filter is used to represent an equipment resource typically used to host a filtration procedure with a main objective to carry out a concentration operation to remove ionic species and medium MW solutes from small volumes of water. This equipment may be used by a batch filtration procedure and include other inlet/outlet streams for additional flushing of the equipment, or it may be used by a continuous feed and bleed filtration procedure for its main function. The procedure can only be executed in a batch / semi continuous mode.

For information on the equipment data interface, see Reverse Osmosis Filter: Equipment Tab.