Size / Design Variable |
Filter Area |
Costing Variable |
Filter Area |
|
Costing Variable |
Filter Area in m2 |
|
Emissions Port |
No |
|
Hosts |
Reverse Osmosis (Batch) Procedure
Reverse Osmosis (Feed and Bleed) Procedure
|
A Reverse Osmosis Filter is used to represent an equipment resource typically used to host a filtration procedure with a main objective to carry out a concentration operation to remove ionic species and medium MW solutes from small volumes of water. This equipment may be used by a batch filtration procedure and include other inlet/outlet streams for additional flushing of the equipment, or it may be used by a continuous feed and bleed filtration procedure for its main function. The procedure can only be executed in a batch / semi continuous mode.
For information on the equipment data interface, see Reverse Osmosis Filter: Equipment Tab.