Reverse Osmosis (Batch) Procedure

Overview

A Reverse Osmosis (Batch) Procedure can be created by selecting the following menu option:
Unit Procedures } Filtration } Reverse Osmosis (Batch)

BReverseOsmosisFilter.bmp

 

Operating Mode

Batch/Semi-Continuous

Host Equipment

Reverse Osmosis Filter

Emissions Port (Vent)

No

Special Input/Output Ports

Yes

 

 

Batch reverse osmosis (RO) is mainly used for removing ionic species and medium MW solutes from relatively small volumes of water. Typical applications include water desalination and ultra-pure water production. In the biotech field, RO filters have been used to concentrate and purify antibiotics.

Special Inputs / Outputs

      Filtrate: the designated output port for the filtrate.

Operations

The following operation types are currently supported in the context of this unit procedure:

      Concentrate (Batch), see Batch Concentration (Batch Membrane Filtration)

      Flush, see Flush

      CIP, see Clean-In-Place (CIP)

      Hold, see Holding

      SIP, see Steam-In-Place (SIP)