A Reverse Osmosis (Batch) Procedure can be created by selecting the following menu option:
Unit Procedures } Filtration } Reverse Osmosis (Batch)
|
Operating Mode |
Batch/Semi-Continuous |
Host Equipment |
||
Emissions Port (Vent) |
No |
|
Special Input/Output Ports |
Yes |
|
|
|
Batch reverse osmosis (RO) is mainly used for removing ionic species and medium MW solutes from relatively small volumes of water. Typical applications include water desalination and ultra-pure water production. In the biotech field, RO filters have been used to concentrate and purify antibiotics.
● Filtrate: the designated output port for the filtrate.
The following operation types are currently supported in the context of this unit procedure:
● Concentrate (Batch), see Batch Concentration (Batch Membrane Filtration)
● Flush, see Flush
● CIP, see Clean-In-Place (CIP)
● Hold, see Holding
● SIP, see Steam-In-Place (SIP)
The following procedures offer a similar functionality:
● Reverse Osmosis (Feed and Bleed) Procedure
● Microfiltration (Batch) Procedure
● Ultrafiltration (Batch) Procedure