Column Equilibration (Simplified)

General Description

The main objective of this operation is to estimate the time and buffer required for washing (or equilibrating/rinsing/regenerating) a column.

Unit Procedure Availability

      Gel Filtration Procedure

      Packed Bed Adsorption (PBA) Chromatography Procedure (Simplified)

      Expanded Bed Adsorption (EBA) Chromatography Procedure

Column Equilibration (Simplified): Modeling Calculations

Buffer Volume Calculation

The buffer volume is equal to the bed volume of the column times the volume factor (in packed bed volumes) that is specified by the user.

Wash Flowrate Specifications

In terms of washing flowrate you can either specify the linear velocity, the absolute flowrate, or the relative flowrate. These are inter-related:

ColumnFeedFlowAbs00601.jpg 

eq. (A.163)

ColumnFeedFlowRel00604.jpg 

eq. (A.164)

Process Time Calculation

The process time is calculated using the following equation:

ColumnFeedProcessTime00607.jpg 

eq. (A.166)

The feed (buffer) volume in the above equation is expressed in ‘packed bed volumes’.

Material Balances

All materials used for washing/equilibrating/regenerating a column end up in the waste stream.

Note. Since the flowrate of a wash/equilibration/regeneration stream is adjusted by the model, the user must make sure that the composition of the stream is correct and not worry about the total stream flowrate.

Column Equilibration (Simplified): Interface

The interface of this operation has the following tabs:

      Oper. Cond’s, see Column Wash (Simplified): Oper. Conds Tab

      Labor, etc, see Operations Dialog: Labor etc. Tab

      Description, see Operations Dialog: Description Tab

      Batch Sheet, see Operations Dialog: Batch Sheet Tab

      Scheduling, see Operations Dialog: Scheduling Tab