Rotary Vacuum Filtration Procedure

Overview

A Rotary Vacuum Filtration Procedure can be created by selecting the following menu option:
Unit Procedures } Filtration } Rotary Vacuum Filtration

RotaryVacuumFilter.bmp

 

Operating Mode

Continuous or Semi-Continuous

Host Equipment

Rotary Vacuum Filter

Emissions Port (Vent)

No

Special Input/Output Ports

Yes

 

 

This unit procedure simulates filtration and continuous cake in a rotary vacuum filter (RVF). RVF units are used widely in the food, biochemical, agricultural, and other industries. They can operate continuously and handle large throughputs.

Special Inputs / Outputs

      Wash Water: the designated input port for wash water.

      Feed: the designated input port for the feed stream.

      Cake: the designated output port for the cake.

      Filtrate: the designated output port for the filtrate.

Operations

The following operation types are currently supported in the context of this unit procedure:

      Filter, see Rotary Vacuum Filtration

      CIP, see Clean-In-Place (CIP)

      Hold, see Holding

      SIP, see Steam-In-Place (SIP)

Note that operations CIP, Hold, and SIP are only available in semi-continuous operating mode.

SEe Also

The following procedures offer a similar functionality:

      Plate and Frame Filtration Procedure

      Nutsche Filtration Procedure

      Centrifugation in a Basket Centrifuge (Top Discharge) Procedure