Flash Evaporation Procedure

Overview

A Flash Evaporation Procedure can be created by selecting the following menu option:
Unit Procedures } Phase Change } Flash Evaporation

FlashDrum.bmp

 

Operating Mode

Continuous or Semi-Continuous

Host Equipment

Flash Drum

Emissions Port (Vent)

No

Special Input/Output Ports

Yes

 

 

This unit procedure simulates separation of volatile compounds in a Flash Drum. Several thermodynamic model options are available for handling the VLE calculations.

Special Inputs / Outputs

      Vapor Output: the designated output port for vapor.

      Liquid Output: the designated output port for liquid.

Operations

The following operation types are currently supported in the context of this unit procedure:

      Flash, see Flash Evaporation

      CIP, see Clean-In-Place (CIP)

      Hold, see Holding

      SIP, see Steam-In-Place (SIP)

Note that operations CIP, Hold, and SIP are only available in semi-continuous operating mode.

SEe Also

The following procedures offer a similar functionality:

      Condensation Procedure

      Thin Film Evaporation Procedure

      Continuous (Rigorous) Distillation Procedure