The following table shows the meaning of the variables appearing in this tab, as well as their default values and their generally acceptable range. Note that due to the manner by which the variables are used by the sizing and costing equations, the range of acceptable values may be further reduced.
Variable |
Default Value |
Range |
|
||
◙ Column Diameter |
0.0 m |
Positive |
◙ Max Column Diameter |
4.0 m |
Positive |
◙ Column Height |
0.0 m |
Positive |
● Column Volume |
0.0 L |
Positive |
○ Design Options |
Pressure Drop |
Pressure Drop / Pressure Drop/Length |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output
In Calculate (Design Mode), the user specifies the maximum column diameter and either the pressure drop or the pressure drop to length ratio from the Absorption: Oper. Conds Tab and the systems computes the number of units and the column diameter and height. For more information on the sizing of the absorber column, see Absorption: Modeling Calculations.
In User-Defined (Rating Mode), the user specifies values for Number of Units, column Diameter and Height.
The equipment purchase cost is based on the column diameter and height. It includes cost of the packing material and it is supplied by the built-in model assuming as material of construction CS.
For more information on this equipment, see Absorber or Stripper.
For information on the left-hand side variables and options, see Equipment Data Dialog: Equipment tab.