The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:
Variable |
Default Value |
Range |
|
||
○ Adsorbed? |
No |
Yes/No |
○ Binding % |
0.0 |
0-100 |
● Overall Binding Efficiency (%) |
0.0 |
0-100 |
● Number of Units in Simultaneous Operation |
1 |
Positive |
○ Breakthrough Time (min) |
120.0 |
Positive |
○ Regeneration Time (min) |
60.0 |
Positive |
○ Regeneration Solvent Inlet Stream |
<None> |
Dedicated Input Port |
◙ Regeneration Solvent per Bed Volume (g/L) |
500.0 |
Positive |
◙ Regeneration Solvent per Mass Adsorbate (kg/kg) |
5.0 |
Positive |
○ Power Type |
<Std Power> |
Any Power Type |
○ Fan/Pump Efficiency (%) |
80 |
0-100 |
● Power (kW) |
0.0 |
Positive |
● Linear Velocity (cm/h) |
0.0 |
Positive |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output
The following list describes the available specification choices in this tab; for more details on how these are implemented, see Packed-Bed Adsorption: Modeling Calculations.
•Component Binding Data...
Specify the components that are adsorbed by checking the ‘Adsorbed?’ box and specify the adsorption (binding) percentage for these components.
•Regeneration Solvent Requirements...
You may specify either the Regeneration Solvent Per Bed Volume or the Regeneration Solvent Per Mass Adsorbate.