A Bulk Washing Procedure can be created by selecting the following menu option:
Unit Procedures } Washing } Bulk
|
Operating Mode |
Continuous or Semi-Continuous |
Host Equipment |
||
Emissions Port (Vent) |
No |
|
Special Input/Output Ports |
Yes |
|
|
|
This procedure can be used to model washing of impurities from bulk material using a washer.
● Wash Input: the designated input port for the wash stream.
● Feed: the designated input port for the feed stream.
● Product: the designated output port for the product stream.
● Wash Output: the designated output port for the wash stream.
The following operation types are currently supported in the context of this unit procedure:
● Wash Material, see Bulk Washing
● CIP, see Clean-In-Place (CIP)
● Hold, see Holding
● SIP, see Steam-In-Place (SIP)
Note that operations CIP, Hold, and SIP are only available in semi-continuous operating mode.
The following procedures offer a similar functionality: