The following table shows the meaning of the variables appearing in this tab, as well as their default values and their generally acceptable range. Note that due to the manner by which the variables are used by the sizing and costing equations, the range of acceptable values may be further reduced.
Variable |
Default Value |
Range |
|
||
◙ Horizontal Area |
0.0 m2 |
Positive |
◙ Max Horizontal Area |
400.0 m2 |
Positive |
◙ Number of Plates per Unit |
5 |
Positive |
○ Inclination |
55.0 degrees |
Circular/ |
○ Spacing |
10.0 cm |
Positive |
○ Length |
0.0 m |
Positive |
○ Width |
0.0 m |
Positive |
○ Flow Type |
Cross-Flow |
Cross-Flow |
○ Underground Installation |
Cross-Flow |
Cross-Flow |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output
In Calculate (Design Mode), the user specifies the Maximum Horizontal Area and the system computes the Number of Units and the Number of Plates per Units. For more information on sizing of an IP clarifier tank, see IP Clarification: Modeling Calculations.
In User-Defined (Rating Mode), the user specifies the Number of Units and the Number of Plates per Units.
The equipment purchase cost is based on the total horizontal area, and is calculated by the built in model for a IP clarifier tank with a minimum area of 5 m2. Other parameters that affect the costing is the installation location (underground or above ground) and the material.
For more information on this equipment, see Inclined Plate (IP) Clarifier.
For information on the left-hand side variables and options, see Equipment Data Dialog: Equipment tab.