Size / Design Variable |
Power |
Costing Variable |
Power |
|
Costing Variable |
Power in kW |
|
Emissions Port |
No |
|
Hosts |
Pumping by a Gear Pump Procedure
|
A Gear Pump is used to represent an equipment resource used to host a pumping procedure with a main objective the displacement of fluids by use of the meshing of gears. The procedure can be executed in a batch or continuous mode.
The default maximum power is 3000.0 kW. See also Centrifugal Pump: Equipment Tab.
In Calculate (Design Mode), the user specifies the Maximum Power and the system computes the Number of Units and the Power. See also Pumping (by Centrifugal Pump): Modeling Calculations.
In User-Defined (Rating Mode), the user specifies the Number of Units and the Power.
Equipment purchase cost is based on the total power consumed and material of construction. It is supplied by the built-in model assuming as material of construction SS316 and with a minimum costing power of 200 Watts.