Size / Design Variable |
Heat Transfer Area |
Costing Variable |
Heat Transfer Area |
|
Costing Variable |
Heat Transfer Area in m2 |
|
Emissions Port |
No |
|
Hosts |
|
A Cooler is used to represent an equipment resource typically used to host a cooling procedure with a main objective to decrease the temperature of the material flowing through it. The procedure can be executed in a batch or continuous mode.
In Calculate (Design Mode), the user specifies the Maximum Heat Transfer Area and the system computes the Number of Units and the Heat Transfer Area. See also Cooling: Modeling Calculations.
In User-Defined (Rating Mode), the user specifies the Number of Units and the Heat Transfer Area.
Built-in equipment purchase cost functions are available for three different types of heat exchangers: plate-and-frame, spiral, and shell-and-tube. The cost is based on the total heat transfer area and the material of construction which is assumed to be CS.