|
Size / Design Variable |
Mass Throughput |
Costing Variable |
None |
|
Costing Variable |
Mass Throughput in kg/h |
|
Emissions Port |
No |
|
Hosts |
2-Way Component Splitting Procedure 3-Way Component Splitting Procedure 4-Way Component Splitting Procedure 5-Way Component Splitting Procedure 6-Way Component Splitting Procedure 7-Way Component Splitting Procedure |
A Component Splitter is used to represent an equipment resource typically used to host a splitting procedure with a main objective to split bulk flow streams into two to nine bulk flow streams on component-by-component basis. The procedure can be executed in a batch or continuous mode.
See Throughput: Equipment Tab.
In Calculate (Design Mode), the user specifies the Maximum Throughput and the system computes the Number of Units and the Rated Throughput. If the operating throughput exceeds the maximum throughput, then the system assumes multiple identical units operating in parallel with an operating throughput of less than the maximum.
In User-Defined (Rating Mode), the user specifies the Number of Units and the Rated Throughput. If the operating throughput exceeds the rated throughput of the step (which is equal to the rated throughput of each unit times the number of units), a warning message is displayed advising the user to increase the number of units or reduce the operating throughput.
The equipment purchase cost supplied by the built-in model is zero, however the user may specify his own costing model if he wishes.