The following table shows the meaning of the variables appearing in this tab, as well as their default values and their generally acceptable range. Note that due to the manner by which the variables are used by the sizing and costing equations, the range of acceptable values may be further reduced.
Variable |
Default Value |
Range |
|
||
◙ Surface Area |
0.0 m2 |
Positive |
◙ Max Surface Area |
2500.0 m2 5000.0 m2 |
Positive |
● Tank Volume |
0.0 L |
Positive |
◙ Tank Depth |
3.0 m |
Positive |
○ Tank Area |
Circular |
Circular/ |
○ Length/Width |
4.0 |
Positive |
● Length |
0.0 m |
Positive |
● Width |
0.0 m |
Positive |
● Diameter |
0.0 m |
Positive |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output
In Calculate (Design Mode), the user specifies the Maximum Surface Area and the system computes the Number of Units and the Surface Area. In Design Mode, the Tank Depth is either specified or calculated based on the detention time. In Rating Mode, the tank depth is always specified. For more information on sizing of a clarifier tank, see Clarification: Modeling Calculations.
In User-Defined (Rating Mode), the user specifies the Number of Units and the Surface Area.
The equipment purchase cost is based on the total surface area, and is calculated by the built in model for a clarifier tank with a minimum surface area of 10 m2.
For more information on this equipment, see Clarifier or Thickener.
For information on the left-hand side variables and options, see Equipment Data Dialog: Equipment tab.