The top part of the interface refers to the equipment’s required consumable type and usage cost. The user can choose among consumables of the required type for this equipment registered in the system or user databanks. The required consumable type for each equipment considered is listed below:

Equipment

Required Consumable

 

 

Gel Filtration (GFL) Chromatography Column

Resin

Packed Bed Adsorption (PBA) Chromatography Column

Resin

Expanded Bed Adsorption (EBA) Chromatography Column

Resin

Membrane Adsorber (MA)

Adsorption Membrane

For more information on the properties of each consumable type considered see the corresponding Properties tab:

Required Consumable

Properties tab

 

 

Resin

Consumables Properties Dialog: Resin Properties tab

Adsorption Membrane

Consumable Properties Dialog: Adsorption Membrane Properties tab)

For resins (or membranes) that may last several years, the user may decide to depreciate the first resin (or membrane) fill-in by checking the ‘Is First Resin capitalized’ (or ‘Is First Cartridge capitalized’) check box. Cost/usage related properties are available on the right side. The user can change the replacement frequency of the consumable through this tab. Other consumable properties can be changed from the Consumables Databank Dialog by selecting Databanks / Consumables from the main menu.

The bottom part of the dialog ‘Other Consumables’ table, refers to additional consumables and it is the same as for any other equipment (see Equipment Data Dialog: Consumables Tab).