This tab is part of the Consumable Properties Dialog.
It allows you to view/edit the properties that are specific to an Adsorption Membrane cartridge consumable. This type of consumable is used by a Membrane Adsorber (MA).
The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:
Variable |
Default Value |
Range |
|
||
○ Material |
Sarto-bind Q |
user-specified |
○ Membrane Area (m2) |
2.0 |
Positive |
○ Membrane Thickness (micron) |
270.0 |
Positive |
○ Membrane Layers |
14.185 |
Positive |
● Membrane Volume (mL) |
540.0 |
Positive |
● Bed Frontal Area (cm2) |
1350.0 |
Positive |
● Bed Height (mm) |
4.0 |
Positive |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output