The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:
Variable |
Default Value |
Range |
|
||
○ Operating Temperature (oC) |
20.0 |
Positive |
● Organic Loading ((kg BOD/h)/m3) |
0.0 |
Positive |
○ Hydraulic Loading (L/m2-h) |
833.3 |
Positive |
○ Recycle Ratio |
0.80 |
Positive |
○ Weighing Factor (for NRC model) |
0.90 |
Positive |
○ Temp. Correction Factor (oC) (for Eckenfelder model) |
1.035 |
Positive |
○ Media Type (for Eckenfelder model) |
Random Plastics Media |
- |
○ n-Constant (for Eckenfelder model) |
0.620 |
Positive |
○ Treatability Factor at 20 oC (for Eckenfelder model) |
0.60 |
Positive |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output
The following list describes the available specification choices in this tab; for more details on how these are implemented, see Trickling Filtration: Modeling Calculations.
•Filter Model Data
You may select between two different filter model data. The National Research Council (NRC) model or the Eckenfelder model.
•Filter Media Type (for Eckenfelder model)
For the Eckenfelder model you may select between six different packing media types.