The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:
Variable |
Default Value |
Range |
|
||
○ Removal % |
0.0 |
0 – 100 |
◙ Specific Feed Loading Rate (m3/m2-day) |
7.2 |
Positive |
○ Sludge Volume Index (mL/g) (W&K model) |
120 |
Positive |
○ Sludge Volume Index (mL/g) (D&R model) |
120 |
Positive |
○ Parameter Vo (m/h) |
7.50 |
Positive |
○ Parameter k (mL/g) |
0.74 |
Positive |
○ Particulate Concentration in Sludge (g/liter) |
30.0 |
Positive |
● Detention Time (h) |
3.0 |
Positive |
● Solids Loading (kg/m2-day) |
0.0 |
Positive |
○ Liquid Viscosity (cP) |
1.0 |
Positive |
○ Power Type |
<Std Power> |
Any Power Type |
● Power (kW) |
0.0 |
Positive |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output
The following list describes the available specification choices in this tab; for more details on how these are implemented, see Thickening: Modeling Calculations.
•Detention Time...
The Detention Time is output when the user specifies the tank depth.
•Surface Area Estimation Options...
In Design Mode of calculation, the surface area of the basin(s) can be estimated based either on the Specific Loading Rate or a Solids Settling Flux model.