The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:
Variable |
Default Value |
Range |
|
||
○ Specify Amount |
No |
Yes/No |
◙ Mass (kg) |
0.0 |
Positive |
◙ Volume (L) |
0.0 |
Positive |
○ Waste Type |
<none> |
Any Waste Type |
○ Waste Treatment Cost ($/kg) |
0.0 |
Positive |
◙ Sampling Time (min) |
60.0 |
Positive |
○ Ignore Labor? |
Yes |
Yes/No |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output
The following list describes the available specification choices in this tab; for more details on how these are implemented, see Sampling: Modeling Calculations.
•Sampling from...
The user specifies whether the sample is taken from the gas or the liquid phase.
•Specify Amount...
The user specifies the amount used for sampling (either mass or volume), its waste type and its waste treatment cost.