The following table shows a brief description of the variables appearing in this dialog. The table also displays their default values and their generally acceptable range:
Variable |
Default Value |
Range |
|
||
◙ Ignore Initial Vapor Contents |
True |
True/ |
○ Specification Options |
Ratio |
Ratio/ |
○ Ratio Options |
Mass |
Mass/ |
◙ Mass Ratio |
0.0 |
Positive |
◙ Liquid Solid Volume Ratio |
0.0 |
Positive |
○ Added Amount Options |
Total |
Total/ |
○ Total Initial Options |
Total |
Total/ |
○ Final Amount Options |
Mass |
Mass/ |
◙ Final Mass (kg) |
0.0 |
Positive |
◙ Final Liquid-Solid Volume (L) |
0.0 |
Positive |
◙ Maximum Number of Iterations |
1000 |
Positive Integer |
◙ Relative Error |
0.001 |
10-7- 1.0 |
◙ Component for composition option |
(none) |
Pure Compo-nent |
○ Composition Options |
Mass |
Mass / Concen-ntration |
◙ Mass Percentage (%) |
0.0 |
0.0-100. |
◙ Concentration (g/L) |
0.0 |
Positive |
◙ Maximum Number of Iterations |
1000 |
Positive Integer |
◙ Relative Error |
0.001 |
10-7- 1.0 |
○ Final Temperature Option |
Tempe-rature |
Tempe-rature |
◙ Final Temperature (oC) |
25.0 |
Positive |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output
The following list describes the available specification choices in this tab; for more details on how these are implemented, see Pull In: Modeling Calculations.
Chose whether the initial vapor contents (i.e. inert vapors) will be taken into account in the mass balance. Select one of the following mixing specifications:
● Ratio (Added amount –to initial amount) :In this case you can specify either the mass ratio or the liquid volume ratio between the add-in stream and the initial contents. Furthermore you can ask the numerator of the ratio to be either the mass/volume of the add-in stream or just one (user-selected) component in the add-in stream. In the same spirit, the denominator used to calculate the specified ratio, may be either the total mass (or volume) of the initial contents or the mass (or volume) of a specific (user-selected) component initially present in the vessel.
● Final Amount - either the Final Mass or the Final Liquid-Solid Volume
● A reference component and either its final Concentration or its final Mass Percentage
● Final Temperature: Specify the desired final tmeperature of the contents of the after the material has been pulled in.
The model will set the pull-in amount of the adjustable mix-inlet stream (top stream) in order to meet the specification set by the user. If the specification cannot be met, then a warning message will be displayed during simulation.