Pull-In Advanced Options Dialog

PullInOpAdvancedOptionsDlg.jpg
Variable Definitions, Ranges and Default Values

The following table shows a brief description of the variables appearing in this dialog. The table also displays their default values and their generally acceptable range:

Variable

Default Value

Range

 

◙ Ignore Initial Vapor Contents
Choose whether the initial vapor contents will be taken into account in the mass balances

True

True/
False

○ Specification Options
User may choose to specify the ratio (added amount / initial amount), the final amount or the composition of the pull in stream.

Ratio

Ratio/
Final Amount or
Compo-sition

○ Ratio Options
User may choose to set the mass ratio or the liquid solid volume ratio.

Mass

Mass/
Liquid-Solid Volume

◙ Mass Ratio

0.0

Positive

◙ Liquid Solid Volume Ratio

0.0

Positive

○ Added Amount Options
User may choose the total added amount or the added amount of a specific component

Total

Total/
Compo-nent

○ Total Initial Options
User may choose the total initial amount or the initial amount of a component

Total

Total/
Compo-nent

○ Final Amount Options
User may choose to set the mass final amount or the liquid-solid volume final amount.

Mass

Mass/
Liquid-Solid Volume

◙ Final Mass (kg)

0.0

Positive

◙ Final Liquid-Solid Volume (L)

0.0

Positive

◙ Maximum Number of Iterations
The maximum number of iterations for converging to the specified final liquid-solid volume amount.

1000

Positive Integer

◙ Relative Error
Precision of the convergence calculations

0.001

10-7- 1.0

◙ Component for composition option

(none)

Pure Compo-nent

○ Composition Options
User may choose to set the mass percentage or the concentration of the composition of the selected component

Mass

Mass / Concen-ntration

◙ Mass Percentage (%)

0.0

0.0-100.

◙ Concentration (g/L)

0.0

Positive

◙ Maximum Number of Iterations
The maximum number of iterations for converging to the specified concentration.

1000

Positive Integer

◙ Relative Error
Precision of the convergence calculations

0.001

10-7- 1.0

○ Final Temperature Option
User may choose to set the final temperature of the mixture contents after material has been pulled in.

Tempe-rature

Tempe-rature

◙ Final Temperature (oC)
The final temperature of the mixture

25.0

Positive

○ Output pH
The pH of the mixture.

7.0

 

○ Initial Guess Set by User
Check this box to provide an initial guess for the add-in stream flow.

No

Yes/No

◙ Initial Guess
The initial guess for the add-in stream flow.

0.0

Positive

Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output

Specification Choices / Comments

The following list describes the available specification choices in this tab; for more details on how these are implemented, see Pull In: Modeling Calculations.

Chose whether the initial vapor contents (i.e. inert vapors) will be taken into account in the mass balance. Select one of the following mixing specifications:

●      Ratio (Added amount –to initial amount) :In this case you can specify either the mass ratio or the liquid volume ratio between the add-in stream and the initial contents. Furthermore you can ask the numerator of the ratio to be either the mass/volume of the add-in stream or just one (user-selected) component in the add-in stream. In the same spirit, the denominator used to calculate the specified ratio, may be either the total mass (or volume) of the initial contents or the mass (or volume) of a specific (user-selected) component initially present in the vessel.

●      Final Amount - either the Final Mass or the Final Liquid-Solid Volume

●      A reference component and either its final Concentration or its final Mass Percentage

●      Final Temperature: Specify the desired final temperature of the contents of the after the material has been pulled in.

The model will set the pull-in amount of the adjustable mix-inlet stream (top stream) in order to meet the specification set by the user. If the specification cannot be met, then a warning message will be displayed during simulation.

See Also

●      Pull In: Oper. Conds Tab