The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:
Variable |
Default Value |
Range |
|
||
○ Removed? |
No |
Yes/No |
◙ Removal % |
0.0 |
0 – 100 |
○ Oil in Oil Phase(% v/v) |
10.0 |
Positive |
◙ Terminal Rise Velocity (m/h) |
4.0 |
Positive |
◙ Oil Globule Density (kg/m3) |
900 |
Positive |
◙ Oil Globule Diameter (microns) |
150 |
Positive |
○ Water Phase Viscosity (cP) |
1.0 |
Positive |
● Overflow Rate (m3/m2-day) |
0.0 |
Positive |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output
The following list describes the available specification choices in this tab; for more details on how these are implemented, see Oil Separation: Modeling Calculations.
•Removal %...
The percentage removal of oil globule components is either calculated by the program or specified by the user.