IP Clarification: Mat. Balance Tab

IPClarificationMatBal.jpg
Variable Definitions, Ranges and Default Values

The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:

Variable

Default Value

Range

 

◙ Oil Components Removal %

0.0

0 – 100

◙ Solid Components Removal (%)

0.0

0 – 100

○ Oil Concentration in Oil Stream (g/L)

15.0

Positive

○ Solids Concentration in Sludge Stream (g/L)

15.0

Positive

Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output

Specification Choices / Comments

The following list describes the available specification choices in this tab; for more details on how these are implemented, see IP Clarification: Modeling Calculations.

•Oil Components Removal %...

The percentage removal of oil globule and particulate solid components is either calculated by the program or specified by the user.