The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:
|
Variable |
Default Value |
Range |
|
|
||
|
○ Non-Bed Pressure Drop (kPa) |
5.0 |
Positive |
|
◙ Bed-Pressure Drop Rate (Pa/cm) |
100.0 |
Positive |
|
◙ Fluid Viscosity (cP) |
1.0 |
Positive |
|
○ Fair-Hatch Constant |
6.0 |
Positive |
|
● Clean Bed Pressure Drop (kPa) |
0.0 |
Positive |
|
○ Power Type |
<Std Power> |
Any Power Type |
|
● Power (kW) |
0.0 |
Positive |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output
The following list describes the available specification choices in this tab; for more details on how these are implemented, see Granular Media Filtration: Modeling Calculations.
•Bed Pressure Drop Rate Options...
The pressure drop per bed depth (for a clean bed) is either set by the user or calculated using one of the following models: Carmen-Kozeny, Rose, or Fair-Hatch.