Granular Media Filtration: Press. Drop Tab

GMFiltrationPressDrop.jpg
Variable Definitions, Ranges and Default Values

The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:

Variable

Default Value

Range

 

○ Non-Bed Pressure Drop (kPa)
The pressure drop before and after the bed.

5.0

Positive

◙ Bed-Pressure Drop Rate (Pa/cm)
The pressure drop in the bed per bed length.

100.0

Positive

◙ Fluid Viscosity (cP)
The average viscosity of the fluid in the bed.

1.0

Positive

○ Fair-Hatch Constant
A constant of the Fair-Hatch filtration model.

6.0

Positive

● Clean Bed Pressure Drop (kPa)
The total pressure drop of the clean bed.

0.0

Positive

○ Power Type
Indicates the power type that is used by the operation. Click on the list box to bring up a list of available power types in order to select one.

<Std Power>

Any Power Type

● Power (kW)
The total power consumed for the operation (per cycle).

0.0

Positive

Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output

Specification Choices / Comments

The following list describes the available specification choices in this tab; for more details on how these are implemented, see Granular Media Filtration: Modeling Calculations.

•Bed Pressure Drop Rate Options...