This tab appears on the interface dialog of the Hydrocycloning operation (see Centrifugation in a Hydrocyclone) when the option to size the equipment based on throughput is selected through the Equipment tab of the Hydrocyclone that hosts this operation (see Hydrocyclone: Equipment Tab).
The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:
Variable |
Default Value |
Range |
|
||
○ Pressure Drop (Pa) |
0.0 |
Positive |
● Operating Throughput (per Unit) (m3/h) |
0.0 |
Zero or Positive |
○ Power Type |
<Std Power> |
Any Power Type |
○ (Power Consumption) Efficiency |
100.0 |
(0, 100] |
● Power (kW) |
0.0 |
Positive |
○ Power Dissipation to Heat (%) |
100.0 |
[0,100] |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output
For more details on how the available specification choices in this tab are implemented, see Centrifugation in a Hydrocyclone: Modeling Calculations.