Centrifugation in a Gas Cyclone: Oper. Conds Tab

GasCycloningOperConds.jpg
Variable Definitions, Ranges and Default Values

The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:

Variable

Default Value

Range

 

Velocity of Inlet Gas (m/s)
Note that this value can only be set in Design Mode.

20.0

Positive

Is Power Consumption Set by User?
Check this box to set the power consumption.

No

Yes/No

Power Type
Indicates the power type that is used by the operation. Click on the list box to bring up a list of available power types in order to select one.

<Std Power>

Any Power Type

(Power Consumption) Efficiency
The ratio of ideal to actual power consumption by this operation (for fanning, etc.). Note that this value is not used if the power consumption is set by the user.

100.0

0 – 100

Power (kW)
The total power consumed for the operation (per cycle).

0.0

Positive

Pressure Drop (bar)
The pressure drop in the cyclone.

0.0

Positive

Operating Throughput (m3/h)
The volumetric flow rate of the feed.

0.0

Positive

Symbol Key: User-specified value (always input); Calculated value (always output); Sometimes input, sometimes output

Specification Choices / Comments

Pressure Drop, Power, and Operating Throughput are always output variables. Velocity of Inlet Gas is input in Design Mode and output in Rating Mode. For more details on how these are implemented, see Centrifugation in a Gas Cyclone: Modeling Calculations.