Batch Distillation: Oper. Period Tab

BatchDistilationPeriods.jpg
Variable Definitions, Ranges and Default Values

The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:

Variable

Default Value

Range

 

Reflux Ratio
The reflux ratio for each period.

0.0

Positive

Vapor Rate (kmol/h)
The molar vaporization rate for each period.

0.0

Positive

Vapor Rate (L/h)
The volumetric vaporization rate for each period.

0.0

Positive

Mole % Distilled
The mole percent that is distilled for each period.

0.0

Positive

Output Stream
Indicates the output port that is connected to the output stream of each period. Click on the list box to bring up a list of available output ports in order to select one.

<none>

Any Output Port

Symbol Key: User-specified value (always input); Calculated value (always output); Sometimes input, sometimes output

Specification Choices / Comments

The following list describes the available specification choices in this tab; for more details on how these are implemented, see Batch Distillation: Modeling Calculations.

Operating Periods...

The user can add up to five periods.

Vaporization Rate...