Baghouse Filtration: Oper. Conds Tab

BaghouseFiltrationOperConds.jpg
Variable Definitions, Ranges and Default Values

The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:

Variable

Default Value

Range

 

○ Removal (%)
The percentage of a particulate component that is removed.

0.0

0 – 100

○ Cleaning Time Per Compartment (min)
The actual duration of the cleaning step per compartment.

0.03

Positive

◙ Filtration Time (min)
The actual duration of the operation (per cycle).

1.0

Positive

◙ Max Pressure Drop (kPa)
Note that this value can only be set in Rating Mode.

5.0

Positive

○ Power Type
Indicates the power type that is used by the operation. Click on the list box to bring up a list of available power types in order to select one.

<Std Power>

Any Power Type

● Power (kW)
The total power consumed for the operation (per cycle).

0.0

Positive

◙ Linear Velocity (m/min)
The linear velocity of the feed gas.

0.75

Positive

○ Fan Efficiency (%)
The efficiency of the fan employed during the operation.

80.0

0 – 100

● Run Time (min)

10.4

Positive

● Max Areal Dust Density (kg/m2)

0.0

Positive

Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output

Specification Choices / Comments

The following list describes the available specification choices in this tab; for more details on how these are implemented, see Baghouse Filtration: Modeling Calculations.

•Filtration Time...

The Filtration Time is either specified or calculated based on the Max Pressure Drop. The Calculated option is available only in Rating mode.