3-Way Flow Distribution: Oper. Conds Tab

3WayDistributionOperConds.jpg
Variable Definitions, Ranges and Default Values

The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:

Variable

Default Value

Range

 

Splitting Specification Scalable?

Yes

Yes/No

Stream Name
Indicates the input port that is connected to the respective input stream.

<None>

Dedicated Input Port

Is Flow Set by User?
Check the box next to an input stream to set the corresponding flow of that stream.

Yes

Yes/No

Mass Flow (kg/h or kg/batch)

0.0

Positive

Total Mass Flow (kg/h or kg/batch)

0.0

0 – 100

Setup Time (min)
The amount of time (per cycle) spent before each operation is carried in preparation for the actual execution of the operation. It may involve actions like cleaning, vacuuming, setting up of equipment, etc. which the user opted not to model explicitly.

0.0

Positive

Process Time (min)
The actual duration of the operation (per cycle).

60.0

Positive

Ignore Labor?
Check this box to ignore labor for this operation. This option is used only if the process time is set by a master-slave relationship.

Yes

Yes/No

Operating Throughput per Unit (kg/h)
The mass flow rate of the feed stream divided by the number of equipment units.

0.0

Positive

Symbol Key: User-specified value (always input); Calculated value (always output); Sometimes input, sometimes output

Specification Choices / Comments

The following list describes the available specification choices in this tab; for more details on how these are implemented, see Flow Distribution Operations: Modeling Calculations.

Distribution Options...

Specify whether the flowrate of each stream is set by the user. If the flowrate is not set by the user then it must be set by demand from a process downstream.

Scalable...

Specify whether the absolute amounts for flowrate (set by the user) are scalable with process throughput adjustment. (This implies that if the user chooses to adjust the process throughput by a factor the user-specified flowrates will also be adjusted by the same factor.)

Time Reference...

Choose the time reference for flowrate. The flowrate can be specified by the user to be per Batch, per Cycle, or per Time Average. Depending on whether the procedure is in batch mode or continuous, and the whether process is in batch mode or continuous, certain options may not be available. Specifically the availability of time reference flows depending on the mode of procedure / process is:

Process Mode

Procedure Mode

Time Reference for Flow

 

 

 

Batch

Batch

Batch / Cycle

Batch

Continuous

Batch / Time Average

Continuous

Continuous

Time Average

Continuous

Batch

Cycle / Time Average

Duration Options...

The duration controls appear only if the procedure is in batch mode. In Rating Mode, you can set the process time (and the setup time), allow the process time to be calculated (based on the throughput), or allow the duration to match exactly the duration of another operation either in the same procedure or in another procedure. In Design mode, you must either specify the process time (and the setup time) or allow the duration to match exactly the duration of another operation (either in the same procedure or in another procedure).

If you choose to match the duration of this operation with the duration of another operation, you introduce a master-slave relationship between the two operations. The program will match the setup-time, the process time and the turnaround time of this operation (the ‘slave’) with the corresponding times of the reference operation (the ‘master’ operation). For more on master-slave relationship, see The Scheduling Tab.