The following table summarizes properties of the INX Column Regenerate operation available to the user for inclusion in any custom-made INX Column Regeneration operation form.
Form Field Name |
Field Description |
Type |
Unit Comment |
---|---|---|---|
regenAssocEquip_SV |
The equipment associated with the regeneration stream source |
String |
N/A |
regenStream_SV |
The regeneration stream name |
String |
N/A |
wasteAssocEquip_SV |
The equipment associated with the waste stream outlet |
String |
N/A |
wasteStream_SV |
The waste output stream name |
String |
N/A |
relRegenVol_SV |
The relative regeneration volume |
Numeric |
volumeUnits_SV |
absRegenVol_SV |
The absolute regeneration volume |
Numeric |
volumeUnits_SV |
absFlowrate_SV |
The absolute flowrate |
Numeric |
absFlowrateUnits_SV |
absFlowrateUnits_SV |
The current display units for absolute flowrate |
String |
Variant |