The following table summarizes properties of the Heat Exchanging operation available to the user for inclusion in any custom-made Heat Exchanging operation form.
Form Field Name |
Field Description |
Type |
Unit Comment |
---|---|---|---|
coldTout_SV |
The cold side outlet temperature |
Numeric |
tempUnits_SV |
hotTout_SV |
The hot side outlet temperature |
Numeric |
tempUnits_SV |
pressUnits_SV |
The current display units for pressure |
String |
Variant |
shellDeltaP_SV |
The shell side pressure drop |
Numeric |
pressUnits_SV |
shellInStrm_SV |
The shell side inlet stream name |
String |
NA |
shellInStrmSource_SV |
The shell side inlet stream source equipment |
String |
NA |
shellOutStrm_SV |
The shell side outlet stream name |
String |
NA |
shellOutStrmDest_SV |
The shell side outlet stream destination |
String |
NA |
tempUnits_SV |
The current display units for temperature |
String |
Variant |
tubeDeltaP_SV |
The tube side pressure drop |
Numeric |
pressUnits_SV |
tubeInStrm_SV |
The tube side inlet stream name |
String |
Variant |
tubeInStrmSource_SV |
The tube side inlet stream source |
String |
Variant |
tubeOutStrm_SV |
The tube side outlet stream name |
String |
Variant |
tubeOutStrmDest_SV |
The tube side outlet stream destination |
String |
Variant |
For additional properties, see Operation Single-Value Fields.