● General Operation Variables
● General Fuel Air Combustion Power Generation Operation Variables
● Gas Turbine Power Generation operation specific variables as listed in the following table:
Variable |
Variable ID (varID) |
Data Type |
Extra arg. (val2) and type |
I/O |
Use simplified overall energy balance model or detailed compressor-combustor-turbine model |
bSimplifiedModel_VID |
boolean |
|
O |
Air compressor pressure ratio |
airCompressorPressRatio_VID |
double |
|
I/O |
Air compressor isentropic efficiency |
airCompressorIsentropicEff_ VID |
double |
|
I/O |
Air compressor power |
airCompressorPower_VID |
double |
|
O |
Turbine isentropic efficiency |
turbineIsentropicEff_VID |
double |
|
I/O |
Turbine power output |
turbinePower_VID |
double |
|
O |
Turbine outlet temperature |
turbineOutTemp_VID |
double |
|
O |
Electric generator efficiency |
generatorEff_VID |
double |
|
I/O |
Electric power output |
electricPower_VID |
double |
|
O |
Gas turbine net power output |
netPower_VID |
double |
|
O |
Thermal efficiency of gas turbine |
thermalEff_VID |
double |
|
O |
electric efficiency of gas turbine |
electricalEff_VID |
double |
|
I/O |
●