● General Operation Variables
● Dead-End Filtration specific variables as listed in the following table. Remember to use the GetOperVarVal2 / SetOperVarVal2 when an extra argument (val2) is required:
Variable |
Variable ID (varID) |
Data Type |
Extra arg. (val2) and type |
I/O |
Filtrate Flux |
filtrateFlux_VID |
double |
|
I/O |
Filtrate Volume per Filter Area |
volumePerArea_VID |
double |
|
I/O |
Particulate Component Removal Fraction |
removalFraction_VID |
double |
Component Name (CString) |
I/O |
Particle Concentration Fraction |
particleConcFraction_VID |
double |
|
I/O |
●