The following table shows the meaning of the variables appearing in this tab, as well as their default values and their generally acceptable range. Note that due to the manner by which the variables are used by the sizing and costing equations, the range of acceptable values may be further reduced.
Variable |
Default Value |
Range |
|
||
◙ Rated Throughput |
0.0 L/h |
Positive |
◙ Max Throughput |
20,000.0 L/h |
Positive |
○ Pumping Efficiency |
70.0 % |
Positive |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output
In Calculate (Design Mode), the user specifies the Maximum Throughput and the system computes the Number of Units and the Rated Throughput.
In User-Defined (Rating Mode), the user specifies the Number of Units and the Rated Throughput.
The purchase cost of the equipment is based on the rated volumetric throughput. By default it is calculated by the programs built-in model for a homogenizer with a minimum volumetric throughput of 540 L/h.
For more information on this equipment, see High Pressure Homogenizer.
For information on the left-hand side variables and options, see Equipment Data Dialog: Equipment tab.