GAC Column: Consumables tab

GACColumnConsumable.jpg

This tab is part of the Equipment Data dialog of a Granular Activated Carbon (GAC) Column.

Specification Choices / Comments

The top part of the interface refers to the required consumable usage of the GAC Column. The required consumable type is the ‘GAC Packing’. The user can choose among the consumables of this type registered in the user databank. Consumable related properties, such as particle density, diameter, and void fraction, are displayed on the left side. There is also a choice for either setting the bed bulk density or letting it be calculated based on the void fraction. Cost/usage related properties on the right side. The user can change the usage properties, specifically the replacement frequency of the consumable. All other properties should be changed from the Consumables Databank Dialog by selecting Databanks / Consumables from the main menu.

The bottom part of the dialog ‘Other Consumables’ table, refers to additional consumables and it is the same as for any other equipment (see Equipment Data Dialog: Consumables Tab).