The following table shows the meaning of the variables appearing in this tab, as well as their default values and their generally acceptable range. Note that due to the manner by which the variables are used by the sizing and costing equations, the range of acceptable values may be further reduced.
Variable |
Default Value |
Range |
|
||
◙ Surface Area |
0.0 m2 |
Positive |
◙ Max Surface Area |
1500.0 m2 |
Positive |
○ Tank Depth |
90% |
(0,100] |
○ Tank Geometry |
Rectangular |
Circular / Rectangular |
○ Diameter |
0.0 m |
Positive |
○ L/W |
4.0 |
Positive |
○ Length |
0.0 m |
Positive |
○ Width |
0.0 m |
Positive |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output
In Calculate (Design Mode), the user specifies the Maximum Surface Area and the system computes the Number of Units and the Surface Area. the user always specifies the depth of the tank. For more information on the sizing of an equalizer tank, see Equalization: Modeling Calculations.
In User-Defined (Rating Mode), the user specifies the Number of Units and the Surface Area.
Equipment purchase cost is based on the throughput and material of construction. It is supplied by the built-in model assuming as material of construction concrete.
For more information on this equipment, see Equalizer.
For information on the left-hand side variables and options, see Equipment Data Dialog: Equipment tab.