Discrete Washer

Overview

MaterialWasherD.bmp

 

Size / Design Variable

Rated Throughput (in entities/h)

Costing Variable
(Built-in Model)

None

Costing Variable
(User-Defined Model)

Rated Throughput (in parts/min)

Emissions Port

No

Hosts

Discrete Washing Procedure

A Discrete Washer is used to represent an equipment resource that hosts a discrete washing procedure with a main objective to wash impurities from discrete entities. One such type of washer consists of a belt conveyor feeder with a spraying system on top. As the belt conveyor transports discrete entities, an aqueous detergent is sprayed to wash away impurities.

Discrete Washer: Equipment Tab

The Equipment Tab for this unit is similar to that of a Discrete Throughput: Equipment Tab.

Variable Definitions, Ranges and Default Values

The following table shows the meaning of the variables appearing in this tab, as well as their default values and their generally acceptable range. Note that due to the manner by which the variables are used by the sizing and costing equations, the range of acceptable values may be further reduced.

Variable

Default Value

Range

 

Rated Throughput (entities/h):
The operating throughput of a single unit. Used as the sizing variable of this equipment resource.

0.0

Positive

Max Throughput (entities/h)
The desired upper limit of the sizing variable. Used only in design mode to determine if multiple units are required.

10000.0

Positive

Symbol Key: User-specified value (always input); Calculated value (always output); Sometimes input, sometimes output

Sizing: Design Mode

In design mode, the software will size the unit based on the demand on rated throughput by the discrete washing operation executed in the unit. If the rated throughput exceeds the specification for the maximum throughput then the software will assume multiple number of identical units (each with rated throughput equally distributed) that are operated in parallel.

Sizing: Rating Mode

In rating mode, the rated throughput of the unit and the number of units are provided by the user.