Custom Splitter

Overview

CustomSplitter.bmp

 

Size / Design Variable

Mass Throughput

Costing Variable
(Built-in Model)

None

Costing Variable
(User-Defined Model)

Mass Throughput in kg/h

Emissions Port

No

Hosts

Custom Flow Splitting (Bulk Flow) Procedure

 

A Custom Splitter is used to represent an equipment resource typically used to host a bulk stream splitting procedure with a main objective to split bulk flow streams into two flow streams based on the users specifications. The procedure can be executed in a batch or continuous mode.

Custom SPlitter: Equipment Tab

See Throughput: Equipment Tab.

Sizing: Design Mode

In Calculate (Design Mode), the user specifies the Maximum Throughput and the system computes the Number of Units and the Rated Throughput. If the operating throughput exceeds the maximum throughput, then the system assumes multiple identical units operating in parallel with an operating throughput of less than the maximum.

Sizing: Rating Mode

In User-Defined (Rating Mode), the user specifies the Number of Units and the Rated Throughput. If the operating throughput exceeds the rated throughput of the step (which is equal to the rated throughput of each unit times the number of units), a warning message is displayed advising the user to increase the number of units or reduce the operating throughput.

Costing

The equipment purchase cost supplied by the built-in model is zero, however the user may specify his own costing model if he wishes.