Variable Definitions, Ranges and Default Values

The following table shows the meaning of the variables appearing in this tab, as well as their default values and their generally acceptable range. Note that due to the manner by which the variables are used by the sizing and costing equations, the range of acceptable values may be further reduced.

Variable

Default Value

Range

 

Diameter
The diameter of the basket.

1.0 m

Positive

Max Diameter
The maximum diameter of the basket.

2.0 m

Positive

Height / Diameter
The height over diameter ratio

0.7

Positive

Height
The height of the basket.

0.7 m

Positive

Filter Area

2.199 m2 

Positive

Vessel Volume

549.779 L

Positive

Symbol Key: User-specified value (always input); Calculated value (always output); Sometimes input, sometimes output

Sizing: Design Mode

In Calculate (Design Mode), the user specifies the Maximum Diameter and the system computes the Number of Units and the Diameter.

Sizing: Rating Mode

In User-Defined (Rating Mode), the user specifies the Number of Units and the Diameter.

The Height to Diameter ratio is always specified by the user and the Filter Area and Vessel Volume are always calculated by the system.

For more information on sizing of centrifuges, see Centrifugation: Modeling Calculations.

Costing

The purchase cost of the equipment is based on the diameter of the basket. By default it is calculated by the programs built-in model for a Basket Centrifuge with a top discharge.

For more information on this equipment, see Basket Centrifuge.