The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:
Variable |
Default Value |
Range |
|
||
○ Heating Agent Name |
<Steam> |
Any Heating Agent |
● Inlet Temp. (oC) |
152.0 |
Positive |
● Outlet Temp. (oC) |
152.0 |
Positive |
◙ Relative Heating Agent Flowrate ((kg/h)/m3 of Drum) |
500.0 |
Positive |
◙ Absolute Heating Agent Flowrate (kg/h) |
0.0 |
Positive |
○ Power Type |
<Std Power> |
Any Power Type |
◙ Specific Power (kW/m3) |
20.0 |
Positive |
◙ Total Power (kW) |
0.0 |
Positive |
◙ Power Per Unit (kW) |
0.0 |
Positive |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output
The following list describes the available specification choices in this tab; for more details on how these are implemented, see Tablet Coating: Modeling Calculations.
•Heating Requirement...
Please note that you can select whether to set the absolute or relative heating agent flowrate (in terms of the drum volume).
•Specific Power...
You can select whether to set the total or specific power (in terms of the drum volume).