The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:
Variable |
Default Value |
Range |
|
||
○ Coated Tablet Name |
Coated Tablet |
Any Text |
○ Amount per Tablet (g or mL) |
0.0 |
Positive |
● Coating Stream |
<None> |
Dedicated Input Port |
○ Volatile ? |
<No> |
Yes/No |
◙ Removal (%) |
0.0 |
0-100 |
● Air Stream |
<None> |
Dedicated Input Port |
◙ Relative Air Stream Flowrate ((m3/h)/L of Drum) |
10.0 |
Positive |
◙ Absolute (STP) Air Stream Flowrate (m3/h) |
1000.0 |
Positive |
○ Setup Time |
0.0 |
Positive |
○ Process Time |
60.0 |
Positive |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output
The following list describes the available specification choices in this tab; for more details on how these are implemented, see Tablet Coating: Modeling Calculations.
You can specify the amount of coating solution per tablet either in terms of mass or volume. If there is solvent evaporation please specify the components that evaporate and their evaporation fractions.