The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range. Note that due to how the variables are used in the modeling equations, the range of acceptable values may be further reduced; for more details, see Pressurization: Modeling Assumptions & Constraints.
Variable |
Default Value |
Range |
|
||
○ Pressurization Gas |
<none> |
Any Gaseous Stock Mixture or Pure Component |
○ Supply Temp. (oC) |
25.0 |
Positive |
● Volume Consumption (L) |
0.0 |
Positive |
● Mass Consumption (kg) |
0.0 |
Positive |
● Initial System Pressure (bar) |
1.01325 |
Positive |
○ Final System Pressure (bar) |
1.1 |
Positive |
○ Setup Time (min) |
0.0 |
Positive |
○ Pressurization Time (min) |
360.0 |
Positive |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output
The following list describes the available specification choices in this tab; for more details on how these are implemented, see Pressurization: Modeling Calculations.
•Source of Pressurization Gas...
The pressurization gas can be selected from the lists of registered pure components and stock mixtures.
•Consumption Volume/Mass...