PBA Column Loading (Simplified): Oper. Conds Tab

PBA_ColumnLoadOperConds.jpg
Variable Definitions, Ranges and Default Values

The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:

Variable

Default Value

Range

 

Resin Binding Capacity (mg/ml)
The maximum mass that can bind to the resin volume.

20.0

Positive

Linear Velocity (m/h)
The linear velocity of the feed in the bed.

3.0

Positive

Absolute Flowrate (L/h)
The volumetric flowrate of the feed in the bed.

0.0

Positive

Relative Flowrate (BV/h)
The volumetric flowrate of the feed in the bed expressed as number of bed volumes per time unit.

0.0

Positive

Empty Bed Contact Time (h)
The amount of time it takes for a feed volume of material to flow through an empty bed.

0.0

Positive

Binding %
The amount of a component that binds to the resin expressed as percentage of its inlet mass.

0.0

0 – 100

Yield %

0.0

0 – 100

Ignore in Sizing?
Check the box next to a component to ignore the binding percentage of that component in equipment sizing calculations.

No

Yes/No

Resin Capacity Utilization (%)

100.0

0 – 100

Waste Outlet Stream
Indicates the output port that is connected to the waste outlet stream. Click on the list box to bring up a list of available output ports in order to select one.

<none>

Any Output Port

Symbol Key: User-specified value (always input); Calculated value (always output); Sometimes input, sometimes output

Specification Choices / Comments

The following list describes the available specification choices in this tab; for more details on how these are implemented, see PBA Column Loading (Simplified): Modeling Calculations.

Loading Flowrate Options...

If the loading time is calculated based on loading flowrate, then you can choose among four different options for specifying the loading flowrate: you can specify the feed’s linear velocity, or its volumetric flowrate, or its relative flowrate (in bed volumes) in the bed, or the empty bed contact time (the amount of time it takes for a feed volume of material to flow through an empty bed). Any variable that is not specified will be calculated by the program.

Binding Capacity...

It refers to all components that bind to the resin.

Recovery Yield...