Frying: Oper. Conds Tab

FryingOperConds.jpg
Variable Definitions, Ranges and Default Values

The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:

Variable

Default Value

Range

 

Recirculating Flowrate (kg/h)

0.0

Positive

Volume of Oil In the Fryer (m3)

1.0

Positive

Turnover Time (h)

4.0

Positive

Inlet Temperature (°C)

165.0

Positive

Min Outlet Temperature (°C)

110

Positive

Outlet Temperature (°C)

130

Positive

Heat Transfer Efficiency (%)
The heat transfer efficiency of the operation.

100.0

(0,100)

Heating Agent Name
Indicates the heating agent that is used for the operation. Click on the list box to bring up a list of available heating agents in order to select one.

<Steam (High P)>

Any Heating Agent

Inlet Temp. (oC)
The inlet temperature of the heating agent.

242.0

Positive

Outlet Temp. (oC)
The outlet temperature of the heating agent.

242.0

Positive

Rate (kg/h)
The mass flow rate of the heating agent.

0.0

Positive

Heat Transfer Efficiency(%)
The heating agent consumption efficiency. Specify a value below 100% to account for heat losses to the surroundings when a heating agent is used.

100.0

[0,100)

Setup Time (min)
The amount of time (per cycle) spent before each operation is carried in preparation for the actual execution of the operation. It may involve actions like cleaning, vacuuming, setting up of equipment, etc. which the user opted not to model explicitly.

0.0

Positive

Process Time (min)
The actual duration of the operation (per cycle).

60.0

Positive

Ignore Labor?
Check this box to ignore labor for this operation. This option is used only if the process time is set by a master-slave relationship.

Yes

Yes/No

Operating Throughput (kg/h)

0.0

Positive

Residence Time of Product In Fryer (s)

100.0

Positive

Makeup Oil Inlet Stream
Indicates the input port that is connected to the makeup oil inlet stream. If an input stream is already present at the selected port, then the button next to the selection is active. Click on the button to bring up the attached stream’s simulation dialog in order to provide its composition.

<None>

Dedicated Input Port

Makeup Oil Flowrate (kg/h)
The mass flow rate of the makeup oil stream.

0.0

Positive

Symbol Key: User-specified value (always input); Calculated value (always output); Sometimes input, sometimes output

Specification Choices / Comments

The following list describes the available specification choices in this tab; for more details on how these are implemented, see Frying: Modeling Calculations.

Duration...

The duration controls appear only if the procedure in batch mode. In Rating Mode, you have a choice to either set the process time (and the setup time) or to allow the process time to be specified (based on the throughput). In Design mode, you must specify the process time (and the setup time) in order for the program to calculate the rated throughput.