Variable Definitions, Ranges and Default Values

The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:

Variable

Default Value

Range

 

Power Type
Indicates the power type that is used by the operation. Click on the list box to bring up a list of available power types in order to select one.

<Std Power>

Any Power Type

Corona Power Ratio (Watt/(m3/min))

10.0

Positive

Corona Current Ratio (mA/m2)

0.40

Positive

Corona Constant (m2 (m/s) / Watt)

1.019

Positive

Power (kW)
The total power consumed for the operation (per cycle).

0.0

Positive

Pressure Drop (kPa)

0.20

Positive

Fan Efficiency (%)
The efficiency of the fan employed during the operation.

80.0

0 – 100

Symbol Key: User-specified value (always input); Calculated value (always output); Sometimes input, sometimes output