The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:
Variable |
Default Value |
Range |
|
||
● Discrete Throughput (per unit) (entities/h) |
0.0 |
Positive |
● Operating Throughput (per unit) (kg/h) |
0.0 |
Positive |
○ Setup Time (min) |
0.0 |
Positive |
◙ Process Time (min) |
60.0 |
Positive |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output
The following list describes the available specification choices in this tab; for more details on how these are implemented, see Discrete Grinding: Modeling Calculations.
The Discrete Throughput is based on the input stream.
•Duration Options...
In Rating Mode, you can set the process time (and the setup time) or allow the process time to be calculated (based on the throughput of the units). In Design mode you must either specify the process time (and the setup time).