The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:
Variable |
Default Value |
Range |
|
||
○ Residence Time (h) |
1.0 |
Positive |
○ Working / Vessel Volume (%) |
90.0 |
(0,100) |
● Working Volume |
0.0 |
Positive |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output
In this case (Design Mode of equipment sizing), the Residence Time and Working/Vessel Volume Ratio are used for sizing the vessel. The Working to Vessel Volume Ratio must be between the minimum and maximum working to vessel volume ratio limits of the equipment.