The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:
Variable |
Default Value |
Range |
|
||
○ Final Temperature (oC) |
25.0 |
Positive |
◙ Heating Duty (kcal/h) |
0.0 |
Positive |
◙ Cooling Duty (kcal/h) |
0.0 |
Positive |
○ Agent |
<Chilled Water> |
Any Heat Transfer Agent |
● Inlet Temp. (oC) |
5.0 |
Positive |
● Outlet Temp. (oC) |
10.0 |
Positive |
● Rate (kg/h) |
0.0 |
Positive |
○ Heat Transfer Efficiency(%) |
100.0 |
[0,100) |
○ Pressure Set by User? |
No |
Yes/No |
◙ Pressure (atm) |
1.0 |
Positive |
○ Power Type |
<Std Power> |
Any Power Type |
◙ Specific Power (Per Volume) (kW/m3) |
0.0 |
Positive |
◙ Total Power (kW) |
0.0 |
Positive |
◙ Power Per Unit (kW) |
0.0 |
Positive |
○ Power Dissipation to Heat (%) |
100.0 |
[0,100] |
○ Allow for Split After Storage |
No |
Yes/No |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output
The following list describes the available specification choices in this tab; for more details on how these are implemented, see Continuous Storage: Modeling Calculations.
•Pressure...
The pressure of the system, if not specified by the user, is set equal to the pressure of the previous operation.
•Allow for Split After Storage...
If you check the option ‘Allow for a Split After Storage’ then the Split Tab becomes available. This tab allows you to specify either total flow or specific component splits to the various streams exiting the vessel.