This tab appears on the interface dialog of the following operation:
The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:
Variable |
Default Value |
Range |
|
||
◙ Linear Velocity (cm/h) |
300.0 |
Positive |
◙ Absolute Flowrate (m3/h) |
0.0 |
Positive |
◙ Relative Flowrate (BV/h) |
0.0 |
Positive |
◙ Relative Volume (per Cycle, per Unit) (BV) |
30.0 |
Positive |
◙ Absolute Volume (per Cycle, per Unit) (L) |
0.0 |
Positive |
◙ Regeneration Time (min) |
30.0 |
Positive |
○ Inlet Stream (of Regeneration Buffer) |
In #1 |
Any Input Port |
○ Outlet Stream (of Regeneration Buffer) |
Out #8 |
Any Output Port |
○ Remove Membrane Contents ? |
No |
Yes/No |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output
The following list describes the available specification choices in this tab; for more details on how these are implemented, see Column Regeneration: Modeling Calculations.
•Regeneration Time Options...
You may choose whether process time is set or calculated. If the process time is set you have the option to specify either the buffer’s Volume (per cycle, per unit) or its Flowrate. If the process time is calculated then you must set both the Flowrate and the Volume.
•Buffer Volume Options...
If the process time and buffer volume are set by user, or if the process time is calculated, you can specify the buffer volume. Either the absolute volume (per batch cycle and per equipment unit) or the relative volume (in bed volumes) can be set. Any variable that is not specified will be calculated by the program.
•Buffer Flowrate Options...
If the process time and buffer flowrate are set by user, or if the process time is calculated, you can specify the buffer flowrate. You can choose among three different options for specifying the buffer flowrate: you can specify the buffer’s linear velocity in the bed, or its volumetric flowrate in the bed, or its relative flowrate (in bed volumes). Any variable that is not specified will be calculated by the program.
•Composition of Inlet Stream...
To specify the composition of the regeneration buffer’s inlet stream, click on the Edit Composition button. That brings up the dialog of that stream and allows you to specify its composition. Please note that the flowrate of that stream will be adjusted by the program during simulation.